Case study: Power transformer tanks

U.S. energy OEM | Manufacturing case study

Power transformer tanks

Engineering development, dimensional control and large-scale painting.

Request a quote →Download capabilities and case studies (PDF)
Worker inspecting a power transformer tank with a Creaform scanner and reference targets
Creaform dimensional inspection. Reference targets support measurement alignment.

6 × 5 × 2.5 m · 15–20 metric tons · Approximately 50 units/year

Approximate dimensions. Weight includes the tank, cover and loose items.

Ongoing supply since 2025

IONSA supplies power transformer (PT) tanks to a U.S. energy OEM. The program has been active since 2025, with approximately 50 units supplied annually. Materials include ASTM A572 Grade 50 and stainless steel.

Challenge: engineering development and painting

The program required engineering development and a painting process suited to large tank assemblies. IONSA addressed these challenges using engineering software and its large paint booth, with coating requirements based on IEEE C57.12.28.

Dimensional and weld inspection

Dimensional verification uses Creaform CMM and 3D scanning equipment. In-house AWS CWI expertise supports weld inspection, with RT, UT, MT and PT (liquid penetrant testing) used according to project requirements. Pressure testing is performed when required.

Delivery to U.S. customers

The program is supported by IONSA’s experience in logistics and Mexico–U.S. border crossings. Most of the company’s production is supplied to the United States.

Program result

An ongoing supply program combining engineering development, fabrication, dimensional and weld inspection, and painting for large transformer tanks.

Discuss your tank program

Send drawings, materials, coating specifications, quantities, delivery requirements and inspection plans.

Request a quote →